Frequency Response Settings: 35 Hz to 18 kHz
Max Spl: 152 dB
Impedance: 20 kOhm (balanced)
Max Input Level: 25 dBu
Wiring: XLRF, Pin 1 chassis, pin 2 +, pin 3 – Separate loop-thru XLRM (for analog signal only)
Lf Transducer: LF 2× 15-in cone, 4 in voice coil
Mf Subsystem: MF 6× 5-in cone, 38mm voice coil
Hf Transducer: HF 14×1-in exit, 35mm voice coil
Nominal Beamwidth: Horz: 70° (for single column; scalable up to 360° utilizing multiple columns) Vert: Adaptive
Power Handling: LF 2 x 1,700W MF 6 x 350W HF 14 x 350W
Connections:
Neutrik® powerCON™ TRUE1™
Analog & AES In/Loop
2x Neutrik® etherCON™ (DANTE enabled)
Dimensions (h × W × D): Height: 17.1 in Width: 45.2 in Depth: 30 in
Net Weight: 285 lbs (129.3 kg)
Calculated Axial Output Limit:
Adapted for 45° Vertical Pattern
Average LF 131 dB
MF 136 dB
HF 137 dB
Peak LF 137 dB
MF 142 dB
HF 143 dB
Adapted for 90° Vertical Pattern
Average LF 131 dB
MF 135 dB
HF 132 dB
Peak LF 137 dB
MF 141 dB
HF 152 dB
Amplifier Type: LF/MF/HF Modified Class D
Maximum Output: LF 2x 1,700W, MF 6x 350W, HF 14x 350W
Driver Protection: Integral DSP limiting
Connector: Neutrik® powerCON™ TRUE1™
Input: 100 V to 240 V
Frequency: 50 Hz to 60 Hz
Power Consumption: Idle 250 W, Peak Draw 1,600 W
Connections: USB A & B, 2x Neutrik® etherCON™
Protocols: USB, Ethernet/Dante
Software: Resolution™ 2 (available at eaw.com)
Indicators: Test, Function, Input (Network, Analog, AES/EBU), Network Status
User Controls: Test, Function